SENSORSD(8) FreeBSD System Manager's Manual SENSORSD(8)
NAME
sensorsd - hardware sensors monitor
SYNOPSIS
sensorsd [-d] [-c check] [-f file]
DESCRIPTION
The sensorsd utility retrieves sensor monitoring data like fan speed,
temperature, voltage and RAID logical disk status from the sysctl(2)
hw.sensors subtree. When the state of any monitored sensor changes, an
alert is triggered. Every alert logs a message to syslog(3) using the
daemon facility. Optionally, an alert can be configured to execute a
command.
By default, sensorsd monitors status changes on all sensors that keep
their state, thus sensors that automatically provide status do not
require any additional configuration. In addition, for every sensor, no
matter whether it automatically provides its state or not, custom low and
high limits may be set, so that a local notion of sensor status can be
computed by sensorsd, indicating whether the sensor is within or is
exceeding its limits.
Limit and command values for a particular sensor may be specified in the
sensorsd.conf(5) configuration file. This file is reloaded upon
receiving SIGHUP.
The options are as follows:
-c check
Check sensors every check seconds. The default is 20. The state
of a sensor is not yet regarded as changed when a check returns a
new state for the first time, but only when the two subsequent
checks both confirm the new state.
-d Do not daemonize. If this option is specified, sensorsd will run
in the foreground.
-f file
Read configuration from file instead of the default configuration
file /etc/sensorsd.conf.
FILES
/etc/sensorsd.conf Configuration file for sensorsd.
SEE ALSO
sysctl(2), sensorsd.conf(5), syslog.conf(5), sysctl(8)
HISTORY
The sensorsd program first appeared in OpenBSD 3.5.
CAVEATS
Certain sensors may erratically flip status from time to time. To guard
against false reports, sensorsd requires two confirmations before
reporting a state change. However, this inevitably introduces an
additional delay in status reporting and command execution, e.g. one may
notice that sensorsd makes its initial report about the state of
monitored sensors not immediately, but by default about 60 seconds after
it is started.
FreeBSD 14.1-RELEASE-p8 January 12, 2018 FreeBSD 14.1-RELEASE-p8